Clamp-On Ultrasonic Flow Meter PCE-TDS 75-ICA Incl. ISO Calibration Certificate

Let’s Discuss

Clamp-on Ultrasonic Flow Meter PCE-TDS 75-ICA incl. ISO Calibration Certificate
Flow meter for fixed installation / Various process connection options / Measurement accuracy of 1% / Up to a pipe diameter of 1200 mm (47.2 in) / Flow rate determination

The flow measuring device is a measuring device for fixed installation. The flow rate of liquids in pipes can be determined with this flow meter. The sensors from the flow meter can be mounted directly on the pipes to be measured without having to cut them open. This enables the flow meter to be installed even during operation.

Another special feature of the flow meter are the different outputs. It is possible to get the flow rate converted by the flow meter into an analog 4… 20-mA signal. Any other measurement value can be transmitted via the pulse output (OCT) from the flow meter. It is also possible to receive the measured values ​​directly via the Modbus outputs RS232 and RS485. This allows the flow meter to be integrated directly into the process control.

HIGHLIGHTS
  • Flow meter for fixed installation
  • Different outputs for process connection
  • For fixed installation
  • For pipe diameters 25 … 1200 mm / 1 in … 47.2 in
  • incl. ISO Calibration Certificate
SPECIFICATION
  • Measuring range ± 0.03 … ± 5 m / s (± 0.09 … ± 16 ft / s)
  • Measurement accuracy ± 1% of the measured value
  • Repeatability 0.2%
  • Pipe diameter 25 … 1200 mm (1 … 48 in)
  • Analog output 0/4 … 20 mA (maximum load 750 Ω)
  • Pulse output 0 … 9999 Hz OCT
  • (Frequency limits are adjustable)
  • Relay output 1 A at 125V AC, 2 A at 30V DC
  • Maximum frequency 1 Hz
  • Communication interface RS232 & RS485
  • Power supply 10 … 36V DC
  • Power consumption 1 A
  • Display LCD, 256 x 128 pixels, with backlight
  • Ambient conditions base -40 … 60°C / -40 … 140°F
  • 0 … 99% RH non-condensing
  • Ambient conditions sensor -40 … 80°C / -40 … 176° F
  • 0 … 99% RH non-condensing
  • Housing material base PC / ABS
  • Protection class base IP 65
  • Protection class sensor IP 68
  • Cable length 9 m / 30 ft
  • Dimensions 16 x 23 x 28 cm / 6.3 x 9.1 x 11
  • Weight 3.2 kg / 7.1 lbs
DELIVERY SCOPE
  • 1 x Clamp-on Ultrasonic Flow Meter PCE-TDS 75-ICA
  • 2 x Flow sensors
  • 1 x Wall mounting set
  • 2 x Hose clamps
  • 1 x Instruction manual
  • 1 x ISO Calibration Certificate

N.B. Calibration certificates are issued specifically for the customer and are excluded from the right of return.